With the idea of ‘Utilising Renewable Energy Sources’ in order to meet our energy needs that are increasing day by day all over the world, our company also serves you in the newly emerging form of investment in this field with the opportunities encouraged to meet the energy needs of the country in areas suitable for investment and with high efficiency.
Investors will need in the GES Project:
- Grounding Materials,
- Power Cables for Inverter Feeds,
- O.G. Supply (XLPE) Cables,
- DC (Solar) Cable,
- O.G. Concrete Pavilion and Cells,
- O.G. Overcurrent and Feeder Management Relays,
- Energy Transmission Line Materials,
- A.G. Main Distribution and Compensation Panel,
- You can get the necessary support from our company in terms of providing reasonable and fast procurement and necessary project service from our company team in accordance with your project in terms of both material supply and realising the commitment.
Project Application Areas
- Installation of O.G and Transformer Installation Works
- Busbar
- Lighting Lightning Rod and Grounding
- CCTV
- Data Systems
- Fire-Security and Camera Systems
- Generator Project Design
- PLC and Scada Automation Projects
- Renewable Energy Project Design
Energy Projecting
Before investing in renewable energy systems such as GES, Wind and Biogas, correct project design is very important for the feasibility of the investment. As TEK ENERJİ, within the scope of consultancy service, we provide all the necessary data to our investors planning renewable energy investment in order to make an investment decision.
Please contact us for your service request regarding our renewable energy project preparation solutions.
Solar Energy Systems Maintenance and Repair
- Routine Maintenance Operations
- Preventive monitoring of AC/DC systems
- External visual monitoring of PV module status
- External visual inspection of the load-bearing construction
- Visual inspection of inverters
- General condition control of cable ducts and cables
- Based on monitoring data, control of the size and sequence voltage of the electricity
- Electrical connection control of arrays, inverters and panels
- Reporting on corrective actions taken
- Preventive and Preventive Maintenance Plan
Panels
- Visual inspection of panels
- Mechanical inspection of the connection of the panels to the carrier system
- Checking the junction boxes and cables of the panels
- Current and voltage measurements of the deviations detected
Carrier System
- Visual inspection of the load-bearing system for damage and corrosion
- Mechanical control of the carrier system and inspection of panel holders
- Elimination of shifts that may occur in the geometry of the carrier system
DC Cabling
- Visual inspection of DC cables
- Inspection of DC cable ducts
- Visual inspection of connection connectors
Inverters
- Visual inspection of inverters
- Cleaning or replacing the air filter
- Cleaning inverters
- Inspection of DC and AC cable connections
- Input-output current/voltage/power control
- Checking the correct operation of the internal fans
AC cabling
- Visual inspection for possible damage
- Inspection of electrical connection points
- Monitoring of surge arresters
- Inspection of fuses and residual current relays
Remote Monitoring System
- Visual inspection of remote monitoring board, monitoring equipment and cabling
- Visual inspection of counters
- Inspection of communication system cables
General
- Visual inspection of wire fences, gates and similar infrastructure elements
- Control and replacement of labelling and warning signs when necessary
- Earthing
- Earthing equipment connection points control
- Making earthing measurements
- LV Distribution Panels
- Visual inspection of distribution panels
- Cleaning distribution boards
- Measuring instruments control
- Fuse, switch, leakage current etc. function control
- MV Switchgears and Equipment
- Visual inspection of MV switchgears and equipment
- Earthing control
- Function control of breakers and disconnectors
- Control system control
- Mechanical handle and lock control
- Fire extinguisher control
- Measuring instruments control
- Intracellular cleaning
- Port control
- Line protection relay function control
- Transformer and Concrete Pavilion
- Visual inspection of transformer and concrete kiosk equipment
- Earthing control
- Transformer function control
- Port control
- MV and LV Headers control
- XLPE cable inspections
- Bar24 control
- Transformer oil control and analysis
- Cleaning inside the pavilion
- Transformer mechanical fixing control
- Energy Transmission Line
- Visual inspection of energy transmission line equipment
- Energy transmission line earthing control
- Power transmission line function control
- All inspections that must be carried out according to the manufacturer's instructions
- Port control
- XLPE traverse connection control
- MV fuse control
GES Panel Cleaning
Panels are cleaned with lime-free pure water. Although it varies according to the region, it is generally sufficient to clean 2-3 times a year. As Tek Enerji, we provide panel maintenance and cleaning services.
You can send your offers and requests to us using our contact information below.
Mail : info@demaymuhendislik.com.tr